When the oxygen compressor compression ratio imbalance measures
When the oxygen compressor compression ratio or the temperature is too high, should stop to check the reasons, troubleshooting before driving. Because the piston ring and guide sleeve wear performance is the compression ratio maladjustment or temperature is too high, if not timely elimination, piston and cylinder dry friction is easy to cause explosion accident. Oxygen compressor inlet filter for at least three months to open the check and remove dust.
Oxygen compressor cooling water should pay attention to at any time, especially with distilled water lubrication cylinder oxygen compressor, under high pressure water for 23 minutes, will cause the explosion accident. When the one or two seal ring Water Leakage, should immediately stop and repair. Cooling water with oxygen compressor should be no oil, no wash in the cooling water tank.
The gas bearing turbine expander uses gas as lubricant, and there is a certain amount of clean air on the clearance surface between the bearing and the journal. When the journal rotates, it does not contact with the bearing and has no friction, and the general speed is higher. Therefore, it is safe production points of gas bearing turboexpander of high precision, handling must be carried out in a clean place, should pay attention to handling code written connection parts, especially rotor factory is the dynamic balance test after the factory, without professional training can not be easily handling, otherwise will cause the machine or vibration is too large.