Treatment measures for pouring concrete in summer
The ultimate strength of concrete poured in a hot climate will be reduced, and the factors affecting it are:
The temperature of concrete is higher.
The condensation and early strength increase rapidly.
With the same slump, the amount of water is increased.
Treatment measures:
Water is sprinkled on the aggregate, and the aggregate is cooled by evaporation of water.
Adding retarder to concrete;
When necessary to replace part of mixing water with ice;
Adding fly ash to regulate the influence of hot climate;
Properly increase the amount of cement per cubic meter of concrete.
The hot climate reduces the air content of concrete, which makes concrete suffer some adverse effects. Mainly:
The durability of hardened concrete is worse.
The ease of mixing of concrete is reduced.
The amount of mixing is reduced.
Treatment measures:
The air content of concrete mixture is often tested.
Increase the dosage of air entraining agent.